● Humiditas: Humiditas relativa non excedere debet 50% ad temperaturam maximam 40℃, et humiditas maior ad temperaturam inferiorem accipi potest.Condensatio quae ex mutatione temperaturae efficitur cavenda est.
● Cum temperatura supra +40℃ est, locus bene ventilandus est. Cum ambitus non est normalis, telecontrollum vel armarium electricum utere, vita operandi inverter a loco installationis afficitur.
● Usu diuturno continuo, vita condensatoris electrolytici in invertere quinque annos non excedens est, vita ventilatoris refrigerandi tres annos non excedens; permutatio et conservatio prius faciendae sunt.
Typus tensionis: 380V et 220V
Capacitas motoria applicativa0.75kw ad 355kw
| Tensio electrica | Numerus exemplaris | Capacitas aestimata (KVA) | Currens emissarius nominalis (A) | Motor Adaptivus (KW) |
| 380V triphasis | RDI67-0.75G-A3 | 1.5 | 2.3 | 0.75 |
| RDI67-1.5G-A3 | 3.7 | 3.7 | 1.5 | |
| RDI67-2.2G-A3 | 4.7 | 5 | 2.2 | |
| RDI67-4G-A3 | 6.1 | 8.5 | quattuor | |
| RDI67-5.5G/7.5P-A3 | 11 | 13 | 5 | |
| RDI67-7.5G/11P-A3 | 14 | 17 | 7.5 | |
| RDI67-11G/15P-A3 | 21 | 25 | 11 | |
| RDI67-15G/18.5P-A3 | 26 | 33 | 15 | |
| RDI67-18.5G/22P-A3 | 31 | 39 | 18.5 | |
| RDI67-22G/30P-A3 | 37 | 45 | 22 | |
| RDI67-30G/37P-A3 | 50 | 60 | 30 | |
| RDI67-37G/45P-A3 | 61 | 75 | 37 | |
| RDI67-45G/55P-A3 | 73 | 90 | 45 | |
| RDI67-55G/75P-A3 | 98 | 110 | 55 | |
| RDI67-75G/90P-A3 | 130 | CL | 75 | |
| RDI67-90G/100P-A3 | CLXX | CLXXVI | 90 | |
| RDI67-110G/132P-A3 | 138 | 210 | 110 | |
| RDI67-132G/160P-A3 | CLXVII | 250 | 132 | |
| RDI67-160G/185P-A3 | 230 | CCCX | CLX | |
| RDI67-200G/220P-A3 | 250 | 380 | ducenti | |
| RDI67-220G-A3 | 280 | 415 | 220 | |
| RDI67-250G-A3 | 340 | 475 | 245 | |
| RDI67-280G-A3 | 450 | 510 | 280 | |
| RDI67-315G-A3 | 460 | DCV | CCCXV | |
| RDI67-350G-A3 | quingenti | DCXL | 350 | |
| 220V monophasica et triphasica | RDI67-0.75G-A2 | 1.4 | 4.0 | 0.75 |
| RDI67-1.5G-A2 | 2.6 | 7.0 | 1.2 | |
| RDI67-2.2G-A2 | 3.8 | 10.0 | 2.2 |
Magnitudo formae vide figuras 2, fig. 3, fig. 4, forma capsulae operationis vide figuram 1.
| Adaptatio motorum ordinariorum (kW) | Modellum inversoris | Magnitudo (mm) | |||||
| Series 220V | A | B | C | G | H | Pessulus securitatis | |
| 0.75-2.2 | 0.75kV-2.2kW | 125 | CLXX | CLXV | 112 | CLX | M4 |
| 3.7-4 | 3.7 kW-4 kW | CL | 220 | CLXXV | 137 | 205 | M5 |
| Adaptatio motorum ordinariorum (kW) | Modellum inversoris | Numerus delineationis | Magnitudo (mm) | |||||
| Series 380V | A | B | C | G | H | Pessulus securitatis | ||
| 0.75-2.2 | 0.75kW-2.2kW | Figura 1 | CLX | 90 | 132.5 | 81 | 147 | M4 |
| 3.7-7.5 | 3.7 kW-7.5 kW | Figura II | 240 | 140 | CLXXVIII | 130 | 230 | M5 |
| XI-XV | 11-15kW | Figura III | 357 | ducenti | 205 | CLII | 330 | M8 |
| 18.5-30 | 18.5kW-30kW | 450 | 270 | 205 | 195 | 425 | M10 | |
| XXXVII-LV | 37kW-55kW | 560 | 320 | 275 | 240 | 535 | M10 | |
| 75-110 | 75kW-110kW | DCCLXV | 380 | 275 | 240 | DCXL | M10 | |
| 132-200 | 132kW-200kW | DCCXXV | quingenti | 290 | 360 | DCCXXXVIII | M10 | |
| 220 | 220kW-280kW | Figura IV | DCC | 1350 | 417 | Installatio armarii consolae | ||
| 250 | ||||||||
| 280 | ||||||||
| CCCXV | 315kW-400kW | mille | MM | DC | ||||
| 350 | ||||||||
| quadringenti | ||||||||
Specificatio
Typus tensionis: 380V et 220V
Capacitas Motoris Applicativa: 0.75kW ad 315kW
Specificationem vide Tabulam 1.
| Tensio electrica | Numerus exemplaris | Capacitas aestimata (kVA) | Currens emissarius nominalis (A) | Motor applicativus (kW) |
| 380V triphasicus | RDI67-0.75G-A3 | 1.5 | 2.3 | 0.75 |
| RDI67-1.5G-A3 | 3.7 | 3.7 | 1.5 | |
| RDI67-2.2G-A3 | 4.7 | 5.0 | 2.2 | |
| RDI67-4G-A3 | 6.1 | 8.5 | 4.0 | |
| RDI67-5.5G/7.5P-A3 | 11 | 13 | 5.5 | |
| RDI67-7.5G/11P-A3 | 14 | 17 | 7.5 | |
| RDI67-11G/15P-A3 | 21 | 25 | 11 | |
| RDI67-15G/18.5P-A3 | 26 | 33 | 15 | |
| RDI67-18.5G/22P-A3 | 31 | 39 | 18.5 | |
| RDI67-22G/30P-A3 | 37 | 45 | 22 | |
| RDI67-30G/37P-A3 | 50 | 60 | 30 | |
| RDI67-37G/45P-A3 | 61 | 75 | 37 | |
| RDI67-45G/55P-A3 | 73 | 90 | 45 | |
| RDI67-55G/75P-A3 | 98 | 110 | 55 | |
| RDI67-75G/90P-A3 | 130 | CL | 75 | |
| RDI67-93G/110P-A3 | CLXX | CLXXVI | 90 | |
| RDI67-110G/132P-A3 | 138 | 210 | 110 | |
| RDI67-132G/160P-A3 | CLXVII | 250 | 132 | |
| RDI67-160G/185P-A3 | 230 | CCCX | CLX | |
| RDI67-200G/220P-A3 | 250 | 380 | ducenti | |
| RDI67-220G-A3 | 258 | 415 | 220 | |
| RDI67-250G-A3 | 340 | 475 | 245 | |
| RDI67-280G-A3 | 450 | 510 | 280 | |
| RDI67-315G-A3 | 460 | DCV | CCCXV | |
| 220V monophasis | RDI67-0.75G-A3 | 1.4 | 4.0 | 0.75 |
| RDI67-1.5G-A3 | 2.6 | 7.0 | 1.2 | |
| RDI67-2.2G-A3 | 3.8 | 10.0 | 2.2 |
Series monophasica 220V
| Motor applicativus (kW) | Numerus exemplaris | Diagramma | Dimensiones: (mm) | |||||
| Series 220 | A | B | C | G | H | pessulus insertus | ||
| 0.75~2.2 | 0.75 kW ~ 2.2 kW | Figura II | 125 | CLXXI | CLXV | 112 | CLX | M4 |
Series trium phasium 380V
| Motor applicativus (kW) | Numerus exemplaris | Diagramma | Dimensiones: (mm) | |||||
| Series 220 | A | B | C | G | H | pessulus insertus | ||
| 0.75~2.2 | 0.75kW ~ 2.2kW | Figura II | 125 | CLXXI | CLXV | 112 | CLX | M4 |
| quattuor | 4kW | CL | 220 | CLXXV | 138 | 208 | M5 | |
| 5.5~7.5 | 5.5kW ~ 7.5kW | 217 | trecenti | 215 | 205 | 288 | M6 | |
| 11 | 11kW | Figura III | 230 | 370 | 215 | 140 | 360 | M8 |
| XV~XXII | 15kW ~ 22kW | 255 | 440 | 240 | ducenti | 420 | M10 | |
| XXX~XXXVII | 30kW~37kW | CCCXV | 570 | 260 | 230 | 550 | ||
| 45~55 | 45kW~55kW | 320 | 580 | CCCX | 240 | 555 | ||
| 75~93 | 75kW ~ 93kW | 430 | DCCLXXXV | 365 | 260 | DCLV | ||
| 110~132 | 110kW ~ 132kW | 490 | DCCCX | 360 | 325 | DCCLXXXV | ||
| CLX~CC | 160kW~200kW | DC | 900 | 355 | 435 | DCCCLXX | ||
| 220 | 200kW ~ 250kW | Figura IV | DCCX | MDCC | 410 | Installatio armarii ad descensum | ||
| 250 | ||||||||
| 280 | 280kW ~ 400kW | DCCC | 1900 | 420 | ||||
| CCCXV | ||||||||
Aspectus et dimensio montaturae
Magnitudo formae vide Fig. 2, Fig. 3, Fig. 4, forma capsulae operationis vide Fig. 1