1. Normae: IEC61643-1 et GB/T18802.1
2. Alta capacitas fluxus fulminis et exonerationis, impetus moduli singularis usque ad 25KA(s)
3. Late adhibeatur in primo gradu tutelae fulmineae systematis apparatus in locis magni periculi fulminei
4. Cum filis internis, structura universa compacta est, filis instituendis commodis.
5. Responsio celerrima, tempus actionis celeris
6. Status laboris manifestus est, viridis (normalis), ruber (Culpa)
| RDU5 | A | XV | 2P | UC420 |
| Codex | Gradus tutelae | Maxima fluxus emissionis | Poloni | Maxima tensio operativa sustinenda |
| Instrumentum Protectionis Contra Impetus Fluctuum | A: Gradus II B: Gradus II | A: XV, XXV, L B: 10, 20, 40, 60, 80, 100 | 1P 2P 3P 4P | UC420 |
| Examen Gradus T1 | |||||
| Numerus exemplaris et specificatio | Maximum continuum tensio operativa UC | Impulsus fulminis claudicatio (10/350μs) | Gradus tutelae sursum (kV) | Respondens tempus ns | Ambitus laboris temperatura ℃ |
| RDU5-A15 | 420V | XV | 2.0 | ≤100 | -40℃~+85℃ |
| RDU5-A25 | 25 | 2.5 | |||
| RDU5-A50 | 50 | 2.5 | |||
| Examen Gradus T2 | |||||||
| Numerus exemplaris et specificatio | Operans aestimatus voltatio | Maximum continuum tensio operativa UC | Gradus tutelae sursum (kV) | Maxima fluxus emissionis Imax (kV) | currentis nominalis In (KA) | Respondens tempus ns | Ambitus laboris temperatura ℃ |
| RDU5-B10 | 220V-380V | 420V | 1.2 | 10 | 5 | ≤25 | -40℃~+85℃ |
| RDU5-B20 | 1.5 | 20 | 10 | ||||
| RDU5-B40 | 1.8 | 40 | 20 | ||||
| RDU5-B60 | 2.2 | 60 | 30 | ||||
| RDU5-B80 | 2.4 | 80 | 40 | ||||
| RDU5-B100 | 2.5 | centum | 60 | ||||
Nota:Protector supertensionis RDU5-B100 structurae CITEL est, reliqui protectores supertensionis seriei RDU5-8 producta structurae OBO sunt.
Gradus II praesidium
Protectio gradus II
| Parametri Technici | Specificatio | |||||
| Gradus tutelae | A: Praesidium primarium | B: Protectio secundaria | ||||
| Fluxus nominalis In (A) | XV, XXV, L | 10, 20, 40, 60, 80, 100 | ||||
| functio | Praesidium contra fulgura et supertensionem, praesidium contra supertensionem impetus. | |||||
| Numerus polorum | 1P, 2P, 3P, 3P + N, 4P | |||||
| Frequentia aestimata (Hz) | 50 | |||||
| Maxima tensio operativa continua Ui (v) | 420 | |||||
| Maxima amplificatio currens Imax (us) | VIII/XX | |||||
| Impulsus fulminis currentis Claustratio (us) | 10/350 | |||||
| I (kA) resistentia circuitus brevis | 25 | |||||
| Tempus responsionis (ns) | ≤100 | ≤25 | ||||
| Gradus tutelae auctus (Kv) | 2.0, 2.5, 2.5 | 1.2, 1.5, 1.8, 2.2, 2.4, 2.5 | ||||
| Gradus tutelae | IP20 | |||||
| Temperatura Referentiae Constituta (℃) | 30℃ | |||||
| genus pollutionis | 2 | |||||
| Capacitas filorum (mm2) | 1-35 | |||||
| Temperatura ambientis operandi (℃) | -XXXV-LXX | |||||
| Altitudo (m) | ≤2000 | |||||
| Temperatura aeris relativa | Cum temperatura aeris relativa +20 ℃ est, non excedit 95%. Cum temperatura aeris relativa +40°C est, 50% non excedere debet; | |||||
| Categoria Installationis | Gradus II et III | |||||
| Modus institutionis | Ferrivia institutionis TH35-7.5 | |||||
| Methodus advenientis | Linea superior advenientis | |||||
| Numerus exemplaris | Maxima tensio operativa continua UC | Impulsus fulminis flacciditas (10/350μs) | Gradus tutelae Sursum (KV) | Tempus responsionis (ns) | Temperatura ambientis operandi ℃ | |
| RDU5-A15 | 420V | XV | 2 | ≤100 | -40°C+85°C | |
| RDU5-A25 | 25 | 2.5 | ||||
| RDU5-A50 | 50 | 2.5 | ||||
Dimensio Adumbrationis et Installationis
Figura 1 Praesidium primarium
Figura 2 Protectio secundaria