RDF16 Series Pulvis Repleti Cartridge Fuse - Cultrum type Contact Fuse (RTO)

RDF16 series fuse e nexus fuse et basi fuse consistit, nexus fuse removere potest fusionem onerantium componentium/stivam eligere.
Vinculum fuse constat ex tubo fuse, liquefacto, filler et indice.Sectio transversalis variabilis liquefactum ex puro cingulo aeris vel filo in altam vim fuse tubo signans est, ibi in tubo fuse repletus cum summa puritate vicus arenae, quae a chemico ut medio arcente processit.Duae fines liquefacti sunt maculae iunctae ut firmiter electricae cum lamina fine (vel lamina connectens), quae cultrum contactum obturaculum-in structuram speciei format.Coniunctio fuse cum indice vel impactore fuso esse potest, potest fusum (indicator) vel ad varia signa converti vel sponte mutare-super ambitum (impulsum) cum fusione liquefactum est.


  • RDF16 Series Pulvis Repleti Cartridge Fuse - Cultrum type Contact Fuse (RTO)
  • RDF16 Series Pulvis Repleti Cartridge Fuse - Cultrum type Contact Fuse (RTO)
  • RDF16 Series Pulvis Repleti Cartridge Fuse - Cultrum type Contact Fuse (RTO)
  • RDF16 Series Pulvis Repleti Cartridge Fuse - Cultrum type Contact Fuse (RTO)

Product Detail

Applicationem

Morbi laoreet

Exempla & Structures

Dimensiones

Product Introduction

RDF16 series fuse e nexus fuse et basi fuse consistit, nexus fuse removere potest fusionem onerantium componentium/stivam eligere.
Vinculum fuse constat ex tubo fuse, liquefacto, filler et indice.Sectio transversalis variabilis liquefactum ex puro cingulo aeris vel filo in altam vim fuse tubo signans est, ibi in tubo fuse repletus cum summa puritate vicus arenae, quae a chemico ut medio arcente processit.Duae fines liquefacti sunt maculae iunctae ut firmiter electricae cum lamina fine (vel lamina connectens), quae cultrum contactum obturaculum-in structuram speciei format.Coniunctio fuse cum indice vel impactore fuso esse potest, potest fusum (indicator) vel ad varia signa converti vel sponte mutare-super ambitum (impulsum) cum fusione liquefactum est.

Basis fuse cum flamma coniungitur - retardatur DMC base tabula plastica, et genus statice contactus figitur, quod genus structurae aperta apparet.Patella anterior terminalis wiring cum filo externo per cochleam iungenda est.Ibi prae-manet duo foramina institutionem.Totus fuse possessor commoda habet dissipationis caloris boni effectus, magnas distrahentes vires, certas contactus et opportunas operationes, etc. Fusio loading component/manubrio fabricatur ex thermosting cinematographica plastica, quae est bona velit effectus, simplex structura et libere agunt. .

Exemplar No.

6

Normalis operating conditio et institutionem conditio

1. Temperatura ambiens:-5℃~+40C, valor mediocris intra 24h+35C non excedit, et valor mediocris intra unum annum minor hoc valore debet.

2. Altitude institutionis locum non excedit 2000m

3 .Atmosphaera conditio

Aer est mundus, cuius relativam humiditatem non excedit L% cum temperatus ambiens in 40 C. Permittitur humiditas relative alta ad humilem comparationem.

temperatus, exempli gratia, humiditas relativa attingere potest 90% cum 20℃, et considerare debet de condensatione quae producta in superficie producti propter variationem temperaturae.

4. intentione

Cum aestimatio voltage 500V est, maximus ratio intentionis valorem non excedit

110% of fusc's aestimavit voltage;Cum voltatio aestimata 690V est, maximus ratio pretii 105% intentionis fuse aestimationis non excedit.

Nota: nexus fuse fuse in minus significanter quam intentione aestimata, indicator fuse vel impactor fuse agere non potest.

5. Installation genus: Ⅲ

VI gradus pollutio: non minus quam 3

Installation positione VII

Haec fuse series perpendiculariter, vel oblique vel oblique institui potest ad illas operationes occasiones sine evidenti concussione, vibrationis impulsu.

Nota: si fuse in diversis a normali institutione statutis condicionis adhibeatur, cum fabrica tractari debet.

Magnitudo Code
A B C D E F G
00C 78.5 54 21 40.5 6 42.5 15
0 78.5 54 29 48 6 60 15
1 135 70 48 48 6 62 20
2 150 70 60 60 6 72 25
3 150 70 67 68 6 82 32

ABUIABACGAAgo_i69AUone6b3AQwoAY4oAY RDF16 Series1 RDF16 Series2 RDF16 Series3

Magnitudo Code
A B C D E F G
00C 78.5 54 21 40.5 6 42.5 15
00 78.5 54 29 48 6 60 15
1 135 70 48 48 6 62 20
2 150 70 60 60 6 72 25
3 150 70 67 68 6 82 32
Magnitudo Rated current A Max.rated potentia consummatio Pn W
IEC 60269 EN 60269 VDE 063 POPULUS
00 16 12 12 7.5 2.1
25 12 12 7.5 2.5
32 12 12 7.5 3.5
40 12 12 7.5 4.5
50 12 12 7.5 4.7
63 12 12 7.5 5.5
80 12 12 7.5 5.7
100 12 12 7.5 8.1
125 12 12 7.5 9.9
160 12 12 - 11.5
1 80 23 23 23 7.5
100 23 23 23 9.3
125 23 23 23 10.2
160 23 23 23 13.9
200 23 23 23 17.7
250 23 23 23 23.5
2 160 34 34 34 12.9
200 34 34 34 17.9
250 34 34 34 22.4
315 34 34 34 25.7
400 34 34 34 30.6
3 315 48 48 48 25.4
400 48 48 48 32.8
500 48 48 48 35.7
630 48 48 48 41.5

Basis fuse cum flamma coniungitur - retardatur DMC base tabula plastica, et genus statice contactus figitur, quod genus structurae aperta apparet.Patella anterior terminalis wiring cum filo externo per cochleam iungenda est.Ibi prae-manet duo foramina institutionem.Totus fuse possessor commoda habet dissipationis caloris boni effectus, magnas distrahentes vires, certas contactus et opportunas operationes, etc. Fusio loading component/manubrio fabricatur ex thermosting cinematographica plastica, quae est bona velit effectus, simplex structura et libere agunt. .

Exemplar No.

6

Normalis operating conditio et institutionem conditio

1. Temperatura ambiens:-5℃~+40C, valor mediocris intra 24h+35C non excedit, et valor mediocris intra unum annum minor hoc valore debet.

2. Altitude institutionis locum non excedit 2000m

3 .Atmosphaera conditio

Aer est mundus, cuius relativam humiditatem non excedit L% cum temperatus ambiens in 40 C. Permittitur humiditas relative alta ad humilem comparationem.

temperatus, exempli gratia, humiditas relativa attingere potest 90% cum 20℃, et considerare debet de condensatione quae producta in superficie producti propter variationem temperaturae.

4. intentione

Cum aestimatio voltage 500V est, maximus ratio intentionis valorem non excedit

110% of fusc's aestimavit voltage;Cum voltatio aestimata 690V est, maximus ratio pretii 105% intentionis fuse aestimationis non excedit.

Nota: nexus fuse fuse in minus significanter quam intentione aestimata, indicator fuse vel impactor fuse agere non potest.

5. Installation genus: Ⅲ

VI gradus pollutio: non minus quam 3

Installation positione VII

Haec fuse series perpendiculariter, vel oblique vel oblique institui potest ad illas operationes occasiones sine evidenti concussione, vibrationis impulsu.

Nota: si fuse in diversis a normali institutione statutis condicionis adhibeatur, cum fabrica tractari debet.

Magnitudo Code
A B C D E F G
00C 78.5 54 21 40.5 6 42.5 15
0 78.5 54 29 48 6 60 15
1 135 70 48 48 6 62 20
2 150 70 60 60 6 72 25
3 150 70 67 68 6 82 32

ABUIABACGAAgo_i69AUone6b3AQwoAY4oAY RDF16 Series1 RDF16 Series2 RDF16 Series3

Magnitudo Code
A B C D E F G
00C 78.5 54 21 40.5 6 42.5 15
00 78.5 54 29 48 6 60 15
1 135 70 48 48 6 62 20
2 150 70 60 60 6 72 25
3 150 70 67 68 6 82 32
Magnitudo Rated current A Max.rated potentia consummatio Pn W
IEC 60269 EN 60269 VDE 063 POPULUS
00 16 12 12 7.5 2.1
25 12 12 7.5 2.5
32 12 12 7.5 3.5
40 12 12 7.5 4.5
50 12 12 7.5 4.7
63 12 12 7.5 5.5
80 12 12 7.5 5.7
100 12 12 7.5 8.1
125 12 12 7.5 9.9
160 12 12 - 11.5
1 80 23 23 23 7.5
100 23 23 23 9.3
125 23 23 23 10.2
160 23 23 23 13.9
200 23 23 23 17.7
250 23 23 23 23.5
2 160 34 34 34 12.9
200 34 34 34 17.9
250 34 34 34 22.4
315 34 34 34 25.7
400 34 34 34 30.6
3 315 48 48 48 25.4
400 48 48 48 32.8
500 48 48 48 35.7
630 48 48 48 41.5
Epistulam tuam hic scribe et mitte nobis