Reactantia in reactantiam inductivam et reactantiam capacitivam dividitur. Classificatio magis scientifica est inductores (inductores) et reactantes capacitivos (capacitores) collective reactores appellari. Attamen, cum inductores primum olim creati sint et reactores appellati sint, quod homines nunc capacitores appellant est reactantia capacitiva, et reactores specifice ad inductores referuntur.
1. Effectus capacitatis in lineis levibus sine onere vel levi onere ad tensionem excessivam frequentiae potentiae reducendam.
2. Distributionem tensionis in longis filis transmissionis emendare.
3. Vis reactiva in linea sub onere levi localiter quantum fieri potest aequilibratur ad fluxum iniustum vis reactivae prohibendum et ad iacturam potentiae in linea reducendam.
4. Cum magnae unitates cum systemate in parallelo coniunguntur, tensio status stabilis frequentiae potentiae in bus altae tensionis reducitur ut parallelum synchronum generatorum facilitet;
5. Resonantiam magneticam generatoris auto-excitatam cum filo longo prohibe.
6. Cum punctum neutrum reactoris per reactorem parvum ad terram connectitur, reactor parvus etiam ad capacitatem lineae inter phases et inter phases et terram compensandam adhiberi potest, ut extinctio automatica currentis arcus secundarii acceleretur, quod commodum ad usum est.
Reactor undae planae DC imprimis adhibetur ad qualitatem retiaculi electrici emendandam et factorem potentiae in circuitu amplificandum. Constat praecipue ex duabus partibus, nucleo ferreo et bobina. Nucleus ferreus est structura columnarum duarum nucleorum, columna nuclei ex chalybe siliconico et lamina insulante constat. Post compositionem, cochlea premitur et sonitum minuitur.
Tensio operativa aestimata 3.1: 400V-1200V/50Hz
3.2 fluxus operationalis aestimatus: 3A ad 1500A/40C
3.3 Robur electricum: nucleus ferreus - bobina 3000VAC/50Hz/10mA/10s sine arcus disruptione
3.4 resistentia insulationis: nucleus ferreus - bobina 3000VDC, valor insulationis maior quam 100M
Sonitus reactoris 3.5 inferior quam 65dB (mensuratus in distantia 1 metri cum reactore)
Gradus tutelae 3.6: IP00
Gradus insulationis 3.7: gradus F
3.8 norma productionis: reactor IEC289:1987

| Numerus exemplaris | Potentia applicabilis (kW) | Currens nominalis (A) | Inductantia (MH) | Gradus insulationis | Forma (mm) | Installatio (mm) | Foramen |
| DCL-6 | 0.75 (1.5) | 6 | 10.6 | F, H | 100 × 95 × 115 | 85 × 75 | 5 |
| DCL-10 | 2.2 | 10 | 6.37 | F, H | 100 × 95 × 115 | 85 × 75 | 5 |
| DCL-10 | 3.7 (4.0) | 10 | 6.37 | F, H | 100 × 95 × 115 | 85 × 75 | 5 |
| DCL-15 | 5.5 | 15 | 4.25 | F, H | 100 × 95 × 115 | 85 × 75 | 5 |
| DCL-20 | 7.5 | 20 | 3.18 | F, H | 140 × 140 × 170 | 65 × 70 | 6 |
| DCL-30 | 11 | 30 | 2.12 | F, H | 140 × 140 × 170 | 65 × 70 | 6 |
| DCL-40 | 15 | 40 | 1.6 | F, H | 140 × 140 × 170 | 65 × 70 | 6 |
| DCL-50 | 18.5 | 50 | 1.27 | F, H | 140 × 140 × 170 | 65 × 70 | 6 |
| DCL-60 | 22 | 60 | 1.06 | F, H | 140 × 140 × 170 | 65 × 70 | 6 |
| DCL-80 | 30 | 80 | 0.79 | F, H | 140 × 160 × 170 | 65 × 85 | 8 |
| DCL-110 | 37 | 110 | 0.56 | F, H | 140 × 160 × 170 | 65 × 85 | 8 |
| DCL-120 | 45 | CXX | 0.53 | F, H | 140 × 160 × 170 | 65 × 85 | 8 |
| DCL-150 | 55 | CL | 0.42 | F, H | 180 × 190 × 210 | 70 × 110 | 8 |
| DCL-200 | 75 | ducenti | 0.32 | F, H | 180 × 190 × 210 | 70 × 110 | 8 |
| DCL-250 | 93 | 250 | 0.25 | F, H | 180 × 185 × 260 | 70 × 110 | 8 |
| DCL-280 | 110 | 280 | 0.22 | F, H | 180 × 185 × 260 | 70 × 110 | 10 |
| DCL-300 | 132 | trecenti | 0.21 | F, H | 180 × 185 × 260 | 70 × 110 | 10 |
| DCL-400 | CLX | quadringenti | 0.16 | F, H | 200 × 200 × 230 | 70 × 120 | 10 |
| DCL-450 | CLXXXVII | 450 | 0.14 | F, H | 220 × 200 × 290 | 90 × 125 | 10 |
| DCL-500 | 200 (220) | quingenti | 0.127 | F, H | 220 × 200 × 290 | 90 × 125 | 10 |
| DCL-600 | 250 (280) | DC | 0.11 | F, H | 230 × 230 × 290 | 90 × 130 | 10 |
| DCL-800 | CCCXV | DCCC | 0.08 | F, H | 230 × 250 × 290 | 90 × 130 | 10 |
| DCL-1000 | quadringenti | mille | 0.063 | F, H | 240 × 270 × 350 | 155 × 130 | 10 |