Series CJX2-K (Contactor AC)

Contactor seriei CJX2-K praecipue ad frequentiam alternantem 50Hz vel 60Hz, tensione operativa aestimata ad 690V, circuitu currenti aestimato ad 9A, adhibetur, ad circuitum remote connectendum et interrumpendum. Etiam cum idoneo releo thermico in initiatorem electromagneticum coniungi potest ad circuitum protegendum qui operationes oneratas habere potest.

Conformat normae IEC/EN60947-4-1.


  • Series CJX2-K (Contactor AC)
  • Series CJX2-K (Contactor AC)
  • Series CJX2-K (Contactor AC)
  • Series CJX2-K (Contactor AC)
  • Series CJX2-K (Contactor AC)

Detalia Producti

Parametrus Technicus Praecipuus

Tabula 1 CJX2-K-06 CJX2-K-08
Currens operandi aestimatus (A) 380V 6 9
AC-3/AC-4 660/690V 3.8 5
Tensio insulationis aestimata (V) DCXC DCXC
Currentis calefactionis conventionalis Ith (A) 20 20
Cavea triphasica moderabilis 220V 1.5 2.2
Potentia motoris (kW) 380V 2.2 4
AC-3 660V/690V 3 4
Frequentia operationis (h⁻¹) Vita electrica AC-3 Duodecim milia Duodecim milia
AC-4 trecenti trecenti
Vita mechanica 3600 3600
Vita electrica (10000 vicibus) AC-3 CXX CXX
AC-4 2.5 2.5
Vita mechanica (10000 vicibus) mille mille
Specificatio Fusibilis RDT16-16 RDT16-20
Potentia spiralis (VA) Trahe 30 30
Tene 4.5 4.5

Characteres Structurae

1. Exemplar utilitatis commoda habet structurae provectae, magnitudinis parvae, ponderis levis, consumptionis energiae humilis, longae vitae operationis, salutis et firmitatis, altae efficaciae technicae, et cetera.

2. Secundum genus quadrati congregari potest, instructus grege contactuum auxiliari, relais thermali aliisque accessionibus, in varietatem productorum derivativorum coniunctus.

3. Contactor non solum cochleis, sed etiam cum ferreo ordinario 35mm, installi potest.

4. Directio contactus nuclei ferrei et contactus contactoris superficiei montis parallela est.

Bloci Contactuum Auxiliarium

Parametrus technicus principalis contactuum auxiliarium typi F4 (LA1-D) vide tabulam 2

Modellum (Tabula II) Grex contactuum Tensio insulationis aestimata V Currentis calefactionis conventionalis A Vita electrica (10⁶ vicibus) Vita mechanica (10⁴ vicibus) Frequentia maxima operationis (t/s) Minimum onus connectendum Adumbratio imaginis
F4-11 1NO + 1NC DCXC 10 0.5~5 mille 3 6V 10mA CJX2-K
F4-20 2NO 3
F4-02 2NC 3
F4-22 2NO + 2NC 3 CJX2-K
F4-40 4NO 3
F4-04 4NC 3
F4-31 3NA+1NC 3
F4-13 1NA+3NC 3

Parametrus technicus principalis contactuum morae aëris typi LA2-D/LA3-D, vide tabulam 3.

Modellum (Tabula 3) Tensio insulationis aestimata V Currentis calefactionis conventionalis A Proprietates morae Ambitus morae (morarum) Mora erroris repetiti Error stabilitatis morae Error temperaturae (‰℃) Grex contactuum Vita electrica (tempora) Vita mechanica Frequentia operationis maxima (temporibus/secundis) Minimum onus connectendum Adumbratio imaginis
LA2-D20 DCXC 10 Mora cum potentia accenditur 0.1~3 ±5 ±30* ±25 NO+NC 0.5~5×10⁶ 2.5×10⁶ 3 6V 10mA  CJX2-K
LA2-D22 0.1~30
LA2-D24 10~180
LA3-D20 Mora cum potentia exstinguitur 0.1~3
LA3-D22 0.1~30
LA3-D24 10~180

Parametrus technicus principalis contactuum auxiliarium generis LA8, vide tabulam 4.

Modellum (Tabula 4) Grex contactuum Tensio insulationis aestimata V Currentis calefactionis conventionalis A Vita electrica (10⁶ vicibus) Vita mechanica (10⁴ vicibus) Frequentia maxima operationis (t/s) Minimum onus connectendum
LA8-11 1NO + 1NC DCXC 10 0.5~5 mille 3 6V 10mA
LA8-20 2NO
LA8-02 2NC
  • Nuntium tuum hic scribe et nobis mitte.