RDX2-125 High Breaker Capacity 1/2/3/4p 6/10kA Miniature Circuit Breaker

RDX2-125 exiguum ambitus ruptor applicatur circuitioni AC50/60Hz, 230V (phasi unius), 400V(2,3, 4 augmentis), pro onere et praesidio brevi.
Ratum current usque ad 125A.Etiam adhiberi potest ut permutatio conversionis infrequens.lt maxime adhibetur in institutione domestica, tum in systematibus commercialibus et industrialelectricalibus distributione.Convenit cum norma IEC/EN60947-2.


  • RDX2-125 High Breaker Capacity 1/2/3/4p 6/10kA Miniature Circuit Breaker
  • RDX2-125 High Breaker Capacity 1/2/3/4p 6/10kA Miniature Circuit Breaker
  • RDX2-125 High Breaker Capacity 1/2/3/4p 6/10kA Miniature Circuit Breaker
  • RDX2-125 High Breaker Capacity 1/2/3/4p 6/10kA Miniature Circuit Breaker

Product Detail

Applicationem

Morbi laoreet

Exempla & Structures

Dimensiones

Product Introduction

RDX2-125 exiguum ambitus ruptor applicatur circuitioni AC50/60Hz, 230V (phasi unius), 400V(2,3, 4 augmentis), pro onere et praesidio brevi.
Ratum current usque ad 125A.t etiam adhiberi potest ut permutatio conversionis infrequens.lt maxime adhibetur in institutione domestica, tum in systematibus commercialibus et industrialelectricalibus distributione.Convenit cum norma IEC/EN60947-2.

RDX2-125 exiguum ambitus ruptor applicatur circuitioni AC50/60Hz, 230V (phasi unius), 400V(2,3, 4 augmentis), pro onere et praesidio brevi.Ratum current usque ad 125A.t etiam adhiberi potest ut permutatio conversionis infrequens.lt maxime adhibetur in institutione domestica, tum in systematibus commercialibus et industrialelectricalibus distributione.

Exemplar No.

11

Cubits technical

   
Pole 1P,2P,3P,4P
Rated voltage Ue (V) 230/400~240/415
Nulla voltage Ui (V) 500
Rated frequency(Hz) 50/60
Rated current in (A) 63,80,100,125
Genus instantaneae remissionis 8-12In
Tutela gradus IP 20
Facultatem fractionis (A) 10000
Ratum impetus sustinere intentionis (1.2/50) Uimp(V) 4000
Mechanica vita (VIII) temporibus
Vita electrica MD temporibus
Ambiens temperatus(°C) -5~ + 40 (cum cotidie mediocris <35).
Terminatio nexu generis Cable / Pin genus busbar

1-1 3-3 4-4

Forma et institutionem dimensionum

12

RDX2-125 exiguum ambitus ruptor applicatur circuitioni AC50/60Hz, 230V (phasi unius), 400V(2,3, 4 augmentis), pro onere et praesidio brevi.Ratum current usque ad 125A.t etiam adhiberi potest ut permutatio conversionis infrequens.lt maxime adhibetur in institutione domestica, tum in systematibus commercialibus et industrialelectricalibus distributione.

Exemplar No.

11

Cubits technical

   
Pole 1P,2P,3P,4P
Rated voltage Ue (V) 230/400~240/415
Nulla voltage Ui (V) 500
Rated frequency(Hz) 50/60
Rated current in (A) 63,80,100,125
Genus instantaneae remissionis 8-12In
Tutela gradus IP 20
Facultatem fractionis (A) 10000
Ratum impetus sustinere intentionis (1.2/50) Uimp(V) 4000
Mechanica vita (VIII) temporibus
Vita electrica MD temporibus
Ambiens temperatus(°C) -5~ + 40 (cum cotidie mediocris <35).
Terminatio nexu generis Cable / Pin genus busbar

1-1 3-3 4-4

Forma et institutionem dimensionum

12

Epistulam tuam hic scribe et mitte nobis